Solar Power Plant

Product Features

  • Photovoltaic (PV) Characteristics
  • Stand-Alone Renewable Energy Systems
  • Solar Array Simulator
  • Micro Grid-Connected PV System
  • Active and Reactive Power Control
  • Multifunctional Energy Measurement
  • Developed Interoperable SCADA System
  • Software for System Simulation and Design

Training Contents

  • Investigation of solar modules

  • Set-up of PV systems in standalone operation

  • Configuration of photovoltaic systems in grid-connected operation

  • Voltage control in a local power grid

  • Power quality improvement

  • Software simulation and design

Specifications

Solar Cell Module

  • Solar Panel : 50 Watt
  • LED Spotlight Lamp :  2000 Watt
  • DC Volt Display :  50 Volt
  • DC Volt Display : 5 Amp.

Battery Charger

  • Power rating : 50 Watt
  • Voltage rating : 12 Volt/ 24 Volt
  • Current rating : 10 Amp.
  • Rechargeable Sealed Lead Acid (SLA) 
  • Battery : 12Volt/ 7.5 Ah

Solar Panel Simulator

  • Voltage ratings :  750 Volt (V-I Curve)
  • Current ratings : 15 Amp (V-I Curve)
  • Power Maximum : 1500 Watt
  • Built-in :  USB 2.0 /RS232/HDMI/CAN/LAN interfaces
  • Touch Screen Operation Panel (HMI) : 15 inch
  • CPU : 2 Core
  • Ram : 8 GB
  • Solid State Drive : 128 GB

SCADA System

  • SCADA remote operation

Inverter Single - phase

  • Inverter 1-Phase Off – grid : Pure Sine wave 300 Watt

Inverter Three - Phase

  • Maximum input power :  5.5 kW
  • Nominal voltage : 370 Vdc
  • Operating voltage : 100 Vdc – 550 Vdc
  • Startup voltage : >125 Vdc
  • Startup power : 30 Watt
  • Absolute maximum voltage : 600 Vdc
  • Full power range : 220 Vdc – 450 Vdc
  • Number of inputs : 2 pairs MC4
  • Rated current :  12 Adc x 2
  • Maximum short circuit current per MPPT (Isc): 15A / 15A
  • Power factor output adjustable : 0.80 leading – 0.80 lagging

Power meter 3 Phase

  • System Support : 3 Phase 3 wire, 3 Phase 4 wire 
  • Display Type Backlit LCD
  •  Accuracy class 1.0
  • Total harmonic distortion up to the 31st harmonic
  • (Phase to Phase ) measurement voltage 35 – 480 V AC 50/60 Hz
  • (Phase to Neutral) measurement voltage 20 – 277 V AC 50/60 Hz
  • Energy Measurement Displayed Vrms, Irms, P, Q, S, PF, f, THDv, THDi
  • Communication Port Protocol Modbus RTU 4800/ 9600/ 19200 Bps, 38.4 Kbps Even/Odd Or None – 2 Wires, Insulation 2500 V
  • Communication Service Remote Monitoring 
  • Wireless Communication : MQTT

System Supported

  • Dimension : D 800 x W 1500 x H 750 mm.
  • Main Power Inlet 1 phase with electric wire : 3 m.
  • Main Power Inlet 3 phase 
  • Circuit Breake  : 1 phase
  • Earth Leakage Circuit Breaker : 1 Phase
  • Pilot Lamp  : 1 unit
  • Emergency stop : 1 unit
  • Dual Outlets Plug: 220 Volt 2 unit
  • Table surface melamine-coated plywood and covered with PVC edges

Solar Array Simulator

  •  Solar Simulator Power Supply
  • Software Interface

  • Simulation Results

  • System Design

  • Real-time monitoring, management and control

Custom Product Requirements