Skip to content
Search
Home
Education
Smart grid technologies
Solar Power Plant
Wind Power Plant
Synchronous Generator
Transmission and Distribution System
Battery Energy Storage System
Local Load
SCADA Management System
Fundamental
DC Circuit
AC Circuit
Electronics Circuit
Embedded Systems
Power Electronics
Single-phase inverter
Three phase inverter
Power Grid 1
Product
Solar Energy System
About us
Home
Education
Smart grid technologies
Solar Power Plant
Wind Power Plant
Synchronous Generator
Transmission and Distribution System
Battery Energy Storage System
Local Load
SCADA Management System
Fundamental
DC Circuit
AC Circuit
Electronics Circuit
Embedded Systems
Power Electronics
Single-phase inverter
Three phase inverter
Power Grid 1
Product
Solar Energy System
About us
Synchronous Generator
Product Features
Synchronous Generator Working Principle
Reactive Power Compensation
Manual/Automatic Synchronization of
Generator with the Power Grid
Parameterization of the automatic cos-phi controller
Multifunctional Energy Measurement
Developed Interoperable SCADA System
Software for System Simulation and Design
Training Contents
Generator connection
Setting the voltage via the excitation current
Load characteristics in generator operation
Power and current distribution in a line network fed by a generator
Parallel operation of a generator and line via the network
Control of active power feed
Control of reactive power feed
Specifications
Generator
Induction Motor Power Rating : 1 hp
Synchronous Generator Power Rating : 1 hp
Inverter Motor Drive Power Rating : 1 kW
On Grid Simulation 3 phase
Circuit breaker 4 poles
CB Current Rating 10 A Selector
Switch 4 poles Selector
Switch Current Rating 10 A
Support Manual and Automatic Grid Connection
SCADA System
SCADA remote operation
Power meter 3 Phase
System Support : 3 Phase 3 wire, 3 Phase 4 wire
Display Type Backlit LCD
Accuracy class 1.0
Total harmonic distortion up to the 31st harmonic
(Phase to Phase ) measurement voltage 35 – 480 V AC 50/60 Hz
(Phase to Neutral) measurement voltage 20 – 277 V AC 50/60 Hz
Energy Measurement Displayed Vrms, Irms, P, Q, S, PF, f, THDv, THDi
Communication Port Protocol Modbus RTU 4800/ 9600/ 19200 Bps, 38.4 Kbps Even/Odd Or None – 2 Wires, Insulation 2500 V
Communication Service Remote Monitoring
Wireless Communication : MQTT
System Supported
Dimension : D 800 x W 1500 x H 750 mm.
Main Power Inlet 1 phase with electric wire : 3 m.
Main Power Inlet 3 phase
Circuit Breake : 1 phase
Earth Leakage Circuit Breaker : 1 Phase
Pilot Lamp : 1 unit
Emergency stop : 1 unit
Dual Outlets Plug: 220 Volt 2 unit
Table surface melamine-coated plywood and covered with PVC edges
SCADA Operation
Real-time monitoring, management and control
Custom Product Requirements
Contact Supplier